Envision

With innovative products and appropriate application technique, it's all possible. If you can envision it, Parex USA can bring it to life.
Get more info.

Details

Standard WaterMaster

The following details can be downloaded directly from Parex in Autocad .DWG format. Simply click on the desired file and you will be prompted by your browser for file saving instructions.

 

Content Download Download Zip
Complete Parex Standard/Optimum WaterMaster System Details
  • All Details
PDF DWG
General Construction
  • SWM G1.01 - Parex Standard/Optimum WaterMaster System Components
PDF DWG
General Construction
  • SWM G1.01B - Parex Standard WaterMaster - GX System Components
PDF DWG
General Construction
  • SWM G1.02 - Framed Wall Application
PDF DWG
General Construction
  • SWM G1.03A - Window Flashing Procedure 1 of 2
PDF DWG
General Construction
  • SWM G1.03B - Window Flashing Procedure 2 of 2
PDF DWG
General Construction
  • SWM G1.04 - Preliminary Mesh Application
PDF DWG
General Construction
  • SWM G1.05 - Inside and Outside Corners
PDF DWG
Expansion Joints
  • SWM E1.01 - Inside Corner Termination
PDF DWG
Expansion Joints
  • SWM E1.02 - Through-System Flashing with Weeps
PDF DWG
Expansion Joints
  • SWM E1.03 - Expansion Joint at Dissimilar Substrates
PDF DWG
Expansion Joints
  • SWM E1.04A - Floor Line Deflection Slip Joint (2D)
PDF DWG
Expansion Joints
  • SWM E1.04B - Floor Line Expansion (ISO)
PDF DWG
Expansion Joints
  • SWM E1.05A - Expansion Joint with Flashing at Floor (2D)
PDF DWG
Expansion Joints
  • SWM E1.05B - Expansion Joint with Flashing at Floor (ISO)
PDF DWG
Expansion Joints
  • SWM E1.06A - Vertical Expansion Joint (2D)
PDF DWG
Expansion Joints
  • SWM E1.06B - Vertical Expansion Joint(ISO)
PDF DWG
Expansion Joints
  • SWM - E1.07 Horizontal Expansion Joint
PDF DWG
Terminations
  • SWM T1.01A - Termination Above Foundation (Vented Track)
PDF DWG
Terminations
  • SWM T1.01B - Termination Above Foundation (Backwrapped)
PDF DWG
Terminations
  • SWM T1.02 - Termination At Grade
PDF DWG
Terminations
  • SWM T1.03A - Cladding Transition (2D)
PDF DWG
Terminations
  • SWM T1.03B - Cladding Transition (ISO)
PDF DWG
Terminations
  • SWM T1.04 - System Termination at ADA Sidewalk
PDF DWG
Terminations
  • SWM T1.05 - Termination at Balcony Slab
PDF DWG
Windows
  • SWM W1.01 - Head Assembly (Window, Door, Louver Vents, Etc)
PDF DWG
Windows
  • SWM W1.02 - Termination at Window Head
PDF DWG
Windows
  • SWM W1.03A - Termination at Metal Flashed Window Sill (2D)
PDF DWG
Windows
  • SWM W1.03B - Termination at Metal Flashed Window Sill (ISO)
PDF DWG
Windows
  • SWM W1.04 - Termination at Window Jamb
PDF DWG
Windows
  • SWM W1.05 - Termination at Finned Window Head
PDF DWG
Windows
  • SWM W1.06 - Termination at Finned Window Sill
PDF DWG
Windows
  • SWM W1.07 - Termination at Finned Window Jamb
PDF DWG
Roof Line
  • SWM R1.01A - Termination at Box Cornice (2D)
PDF DWG
Roof Line
  • SWM R1.01B - Termination at Box Cornice (ISO)
PDF DWG
Roof Line
  • SWM R1.02A - Termination at Soffit With Insulation
PDF DWG
Roof Line
  • SWM R1.02B - Termination at Soffit Without Insulation
PDF DWG
Roof Line
  • SWM R1.03 - Parapet Wall Termination at Cap Flashing
PDF DWG
Roof Line
  • SWM R1.04 - Gravel Stop
PDF DWG
Roof Line
  • SWM R1.05 - Intersection of Roof Cornice at System Wall
PDF DWG
Roof Line
  • SWM R1.06 - Termination at Roof
PDF DWG
Penetrations
  • SWM P1.01 - Fixture Attachment (by others)
PDF DWG
Penetrations
  • SWM P1.02 - Hose Bib (by others)
PDF DWG
Penetrations
  • SWM P1.03 - Downspout Attachment (by others)
PDF DWG
Penetrations
  • SWM P1.04 - Termination at Appliance Sleeve (by others)
PDF DWG
Penetrations
  • SWM P1.05 - Termination at Small Electrical Feature (by others)
PDF DWG
Penetrations
  • SWM P1.06 - Deck Attachment (by others)
PDF DWG
Penetrations
  • SWM P1.07 - Handrail Attachment (by others)
PDF DWG
Aesthetic Features
  • SWM A1.01 - Aesthetic Band and Reveal
PDF DWG

 

 

Disclaimer: The design specifications and construction of the wall shall comply with all building codes and standards. Parex USA installation guidelines are for general information and guidance only and Parex USA specifically disclaims all liability for the use of this design, for design engineering, and for workmanship of any project. The wall assembly shall be designed to prevent condensation within the assembly. The designer and the user shall provide final drawings and specifications.

 

The drawings and any related notes or text contained thereon, are based upon typical requirements of Parex exterior insulation and finish systems and are published strictly as a guide for architectural and construction industry professionals to illustrate typical or general design conditions.

 

These details are not to be used by themselves, and do not constitute design instructions for Parex EIFS application. These details must be used in conjunction with Parex current product specifications, product data sheets, and application instructions.

 

Any details shown are strictly for the purpose of illustrating typical Parex EIFS. Any other materials shown in any details are incidental to the details, and are included only for clarity of the Parex EIFS. Please consult with the manufacturers and/or suppliers of any separate materials for their product specifications and applications instructions.

 

Where site or design conditions not shown in these details are present, or any unusual design is involved, please consult with the Parex USA Technical Department for assistance.

 

PAREX USA DOES NOT WARRANT THE FITNESS OF SUITABILITY OF THESE DETAILS FOR CONSTRUCTION, OR ASSUME ANY LIABILITY FOR USE OF THESE DETAILS. IT IS THE SOLE RESPONSIBILITY OF ANY ARCHITECTURAL OR CONSTRUCTION INDUSTRY PROFESSIONAL TO APPLY THEIR PROFESSIONAL KNOWLEDGE IN UTILIZING THE INFORMATION CONTAINED IN THESE DETAILS.